Miso Motion sample v1

A sample of egocentric (head-worn) recordings of people doing hands-on work. It has 20 clips, each up to 90 s long. The clips come from 20 different operators in a range of trades and settings. Every clip contains one stereo camera pair, a head IMU, and task, environment and operator labels.

Capture setup

  • Device: BitRobot RoboCap V1.1, worn on the head.
  • Cameras: the front stereo pair, left and right. Each records 1920x1080 at 30 fps in H.265.
    • The lenses are wide-angle, about 152° horizontal (vendor specification).
    • The imagery is as captured. It has not been rectified or undistorted.
    • No camera intrinsics, extrinsics or stereo baseline are included.
  • IMU: the /ego/imu topic carries a 3-axis gyroscope (rad/s) and a 3-axis accelerometer (m/s²). The gyroscope is linearly interpolated onto the accelerometer timestamps.
    • The rate differs between units. Each clip records its own measured rate in annotation.json (imu.measured_rate_hz). In this sample it ranges from 197.4 to 202.9 Hz.
    • Only raw angular velocity and linear acceleration are included. There is no orientation estimate.
  • Location: every clip in this sample was recorded in South Korea.

Folder layout

README.md
manifest.csv              one row per clip: labels, trim window, folder and file paths, total size
contact_sheet.html        thumbnail grid with key labels (opens offline)
clips/<clip_id>_<task_id>/          e.g. clips/mm_sample_0001_decorate-baked-pastries-with-icing/
  <clip_id>_<task_id>_raw.mcap          trimmed recording: original camera and IMU topics, schemas and encoding
  <clip_id>_<task_id>_front_left.mp4    H.264, 1920x1080, 30 fps (re-encoded from the H.265 stream)
  <clip_id>_<task_id>_front_right.mp4
  <clip_id>_<task_id>_preview_sbs.mp4   side-by-side preview, left | right, 1280x720 per eye, H.264
  <clip_id>_<task_id>_imu.csv           IMU samples inside the trim window
  <clip_id>_<task_id>_annotation.json   labels and per-clip measurements
  <clip_id>_<task_id>_thumbnail.jpg

Topics in the raw.mcap files

All three topics are protobuf-encoded, and the schemas are embedded in the file.

Topic Schema Content
/top-left-camera/image-raw foxglove.CompressedVideo H.265 Annex-B access units, one per frame
/top-right-camera/image-raw foxglove.CompressedVideo same as the left camera
/ego/imu foxglove.IMUMeasurement (a device-specific schema, embedded in the file) timestamp, angular_velocity xyz, linear_acceleration xyz

The topic names are the device's legacy names. Both cameras belong to the front stereo pair.

Timing

  • All timestamps are Unix epoch nanoseconds.
  • trim_start_ns is the timestamp of the first left-camera frame in the clip.
  • trim_end_ns is the timestamp of the last left-camera frame plus one frame period (33.3 ms).
  • duration_s is (trim_end_ns - trim_start_ns) / 1e9.
  • In the MP4s, frame n of the left file and frame n of the right file are a timestamp-matched pair.
  • In raw.mcap, each camera stream starts on a keyframe. This means a stream can begin up to one frame before trim_start_ns.
  • In some clips the first IMU sample comes up to about 1 s after trim_start_ns. imu.csv and raw.mcap start at the first recorded sample; nothing is padded or interpolated.

Loading

# pip install mcap mcap-protobuf-support
from mcap.reader import make_reader
from mcap_protobuf.decoder import DecoderFactory

with open("clips/mm_sample_0001_decorate-baked-pastries-with-icing/mm_sample_0001_decorate-baked-pastries-with-icing_raw.mcap", "rb") as f:
    reader = make_reader(f, decoder_factories=[DecoderFactory()])
    for schema, channel, message, msg in reader.iter_decoded_messages(topics=["/top-left-camera/image-raw"]):
        h265_access_unit = msg.data   # feed to an H.265 decoder, e.g. PyAV
import pandas as pd, json
imu = pd.read_csv("clips/mm_sample_0001_decorate-baked-pastries-with-icing/mm_sample_0001_decorate-baked-pastries-with-icing_imu.csv")
ann = json.load(open("clips/mm_sample_0001_decorate-baked-pastries-with-icing/mm_sample_0001_decorate-baked-pastries-with-icing_annotation.json"))

The MCAP files also open directly in Foxglove.

Labels and provenance

Each label field in annotation.json is tagged in its provenance block with one of these values:

  • MEASURED: computed from the recording itself. This covers durations, trim window, resolution, frame rate, codec and IMU rate.
  • RECORDED_METADATA: taken from the session metadata recorded with the clip. This covers task, skill group, difficulty, environment, location, NAICS code and operator attributes.

A field with no value is left null. Operator attributes are limited to age range, gender and handedness. The sample contains no model-generated labels (hand pose, action segments or captions).

Downloads last month